EWH

Engineered Wood Hanger

Universal, flexible and simple to install, the EWH is an engineered hanger that has been designed to fulfil a wide variety of installation options.

 

CE-merkitty
Tekninen hyväksyntä
UKCA
Käyttöluokka 2
Electrogalvanized steel 20 µm
Indoor

Tuotteen yksityiskohdat

Ominaisuudet

Material

  • 275 g/m2 Pre-galvanised Mild Steel. 

 

Features

  • Choice of installation options - Top Fix, Face Fix.
  • Hanger supplied with top flange straight so that it can be bent on site to accommodate a range of joist heights.
  • Perforations allow the top flange to be snapped off for face fix installation option.
  • Optional triangular holes for increased download and uplift performances.
  • Seat tab for ease of installation.
  • Seat tab can be bent upwards for installations where the header is deeper than the joist.

 

Suitability

Suitable for use with combinations of the following:

  • Headers: I-Joists, Metal Web Joists, Solid Timber and SIP’s.
  • Joists: I-Joists, Metal Web Joists, and Solid Timber.

(Note: Solid timber refers to LVL, Glulam or Solid Sawn Timber)

 

Tekniset tiedot

Mitat

Height & Width Suitability

Joist Heights
[mm]

Hanger Height
(B)
[mm]

Joist Widths [mm]

38
39

454753586063

69
70

72

75 2*38
2*39

89
90
2*45

2*47

96
97

2*532*582*601222*63

140  2*69 2*70

2*72

147 2*75

2*89 2*90

2*96 2*97

2*1222*147
Hanger Width (A) [mm]
40475056616366727579919699109119122125128142146150182196246296
195, 200, 202195XXXXXX XXXXXXXXXX XXXXXXX
219, 220, 225219XXXXXXXXXXXXXXXXXXXXXXXXX
235, 240235XXXXXXXXXXXXXXXX XXX XX  
245, 250245XXX X X XXXXX X  X X XX  
253, 254253 XX     X X X   X  XX XXX
295295       X    X            
300, 304300XXXXXXXXXXXXXXXXXXXXXXXXX
350, 356350 XX  X XX XXX  X  X      
360360 XX XXXX XXXX XX     X   
373370  X     X   X            
400400 XX XXXXX XXX XX     X   
417, 421417  X     X   X            

 

Product Dimensions

Tuotenro DB nr. NOBB nr. Equivalent IUSE Dimensions [mm] Holes
A B C D E t Flange B Flange C Flange E
Ø5 Ø10 Tri Ø5 Tri Ø5
EWH195/40---401954980400.9846444
EWH195/472385793-IUSE199/48474980400.9846444
EWH195/50--IUSE199/50504980400.9846444
EWH195/56---564980400.9846444
EWH195/61--IUSE199/61614980400.9846444
EWH195/63--IUSE199/63634980400.9846444
EWH195/72---724980400.9846444
EWH195/75---754980400.9846444
EWH195/79---794980400.9846444
EWH195/91--IUSE199/92914980400.9846444
EWH195/96---964980400.9846444
EWH195/99---994980400.9846444
EWH195/109---1094980401.2846444
EWH195/119---1194980401.2846444
EWH195/122---1224980401.2846444
EWH195/125---1254980401.2846444
EWH195/142---1424980401.2846444
EWH195/146---1464980401.2846444
EWH195/150---1504980401.2846444
EWH195/182---1824980401.2846444
EWH195/196---1964980401.2846444
EWH195/246---2464980401.2846444
EWH195/296---2964980401.2846444
EWH200/47--IUSE199/48472004980400.9846444
EWH200/61--IUSE199/61614980400.9846444
EWH200/91--IUSE199/92914980400.9846444
EWH219/40---402194980400.9848444
EWH219/47--IUSE219/48474980400.9848444
EWH219/50--IUSE219/50504980400.9848444
EWH219/56---564980400.9848444
EWH219/61--IUSE219/61614980400.9848444
EWH219/63--IUSE219/63634980400.9848444
EWH219/66--IUSE219/66664980400.9848444
EWH219/72--IUSE219/73724980400.9848444
EWH219/75---754980400.9848444
EWH219/79---794980400.9848444
EWH219/91--IUSE219/92914980400.9848444
EWH219/96---964980400.9848444
EWH219/99---994980400.9848444
EWH219/109---1094980401.2848444
EWH219/119---1194980401.2848444
EWH219/122---1224980401.2848444
EWH219/125---1254980401.2848444
EWH219/128---1284980401.2848444
EWH219/142---1424980401.2848444
EWH219/146---1464980401.2848444
EWH219/150---1504980401.2848444
EWH219/182---1824980401.2848444
EWH219/196---1964980401.2848444
EWH219/246---2464980401.2848444
EWH219/296---2964980401.2848444
EWH235/40---402354980400.98410444
EWH235/47--IUSE239/48474980400.98410444
EWH235/50--IUSE239/50504980400.98410444
EWH235/56--IUSE239/56564980400.98410444
EWH235/61--IUSE239/61614980400.98410444
EWH235/63--IUSE239/63634980400.98410444
EWH235/66--IUSE239/66664980400.98410444
EWH235/72--IUSE239/73724980400.98410444
EWH235/75---754980400.98410444
EWH235/79---794980400.98410444
EWH235/91--IUSE239/92914980400.98410444
EWH235/96---964980400.98410444
EWH235/99--IUSE239/100994980400.98410444
EWH235/109---1094980401.28410444
EWH235/119---1194980401.28410444
EWH235/122---1224980401.28410444
EWH235/128---1284980401.28410444
EWH235/142---1424980401.28410444
EWH235/146---1464980401.28410444
EWH235/182---1824980401.28410444
EWH235/196---1964980401.28410444
EWH240/47--IUSE239/48472404980400.98410444
EWH240/50--IUSE239/50504980400.98410444
EWH240/56--IUSE239/56564980400.98410444
EWH240/61--IUSE239/61614980400.98410444
EWH240/66--IUSE239/66664980400.98410444
EWH240/72--IUSE239/73724980400.98410444
EWH240/91--IUSE239/92914980400.98410444
EWH240/99--IUSE239/100994980400.98410444
EWH245/40---402454980400.98410444
EWH245/472385795--474980400.98410444
EWH245/502400627-IUSE239/50504980400.98410444
EWH245/612385796-IUSE249/61614980400.98410444
EWH245/66---664980400.98410444
EWH245/75---754980400.98410444
EWH245/79---794980400.98410444
EWH245/91--IUSE249/92914980400.98410444
EWH245/96---964980400.98410444
EWH245/99--IUSE249/100994980400.98410444
EWH245/119---1194980401.28410444
EWH245/128---1284980401.28410444
EWH245/146---1464980401.28410444
EWH245/182---1824980401.28410444
EWH245/196---1964980401.28410444
EWH253/47---472534980400.98410444
EWH253/50---504980400.98410444
EWH253/75---754980400.98410444
EWH253/91--IUSE254/92914980400.98410444
EWH253/99---994980400.98410444
EWH253/125---1254980401.28410444
EWH253/146---1464980401.28410444
EWH253/150---1504980401.28410444
EWH253/196---1964980401.28410444
EWH253/246---2464980401.28410444
EWH253/296---2964980401.28410444
EWH295/72--IUSE294/73722954980400.98410444
EWH295/99--IUSE294/98994980400.98410444
EWH300/40---403004980400.98410444
EWH300/472385797-IUSE299/48474980400.98410444
EWH300/502400628-IUSE299/50504980400.98410444
EWH300/56--IUSE299/56564980400.98410444
EWH300/61--IUSE299/61614980400.98410444
EWH300/632385798-IUSE299/63634980400.98410444
EWH300/66--IUSE299/66664980400.98410444
EWH300/72--IUSE299/73724980400.98410444
EWH300/75---754980400.98410444
EWH300/79---794980400.98410444
EWH300/912385799-IUSE299/92914980400.98410444
EWH300/96---964980400.98410444
EWH300/99--IUSE299/100994980400.98410444
EWH300/109---1094980401.28410444
EWH300/119---1194980401.28410444
EWH300/122---1224980401.28410444
EWH300/125---1254980401.28410444
EWH300/128---1284980401.28410444
EWH300/142---1424980401.28410444
EWH300/146---1464980401.28410444
EWH300/150---1504980401.28410444
EWH300/182---1824980401.28410444
EWH300/196---1964980401.28410444
EWH300/246---2464980401.28410444
EWH300/296---2964980401.28410444
EWH350/472385800-IUSE349/48473504980401.28410444
EWH350/502400629--504980401.28410444
EWH350/632385801--634980401.28410444
EWH350/72--IUSE349/73724980401.28410444
EWH350/75---754980401.28410444
EWH350/912385802--914980401.28410444
EWH350/96---964980401.28410444
EWH350/99--IUSE349/100994980401.28410444
EWH350/122---1224980401.28410444
EWH350/142---1424980401.28410444
EWH360/47--IUSE359/48473604980401.28410444
EWH360/502385803--504980401.28410444
EWH360/61--IUSE359/61614980401.28410444
EWH360/63--IUSE359/63634980401.28410444
EWH360/66--IUSE359/66664980401.28410444
EWH360/72--IUSE359/73724980401.28410444
EWH360/79---794980401.28410444
EWH360/91--IUSE359/92914980401.28410444
EWH360/96---964980401.28410444
EWH360/99--IUSE359/98994980401.28410444
EWH360/119---1194980401.28410444
EWH360/122---1224980401.28410444
EWH360/182---1824980401.28410444
EWH370/50---503704980401.28410444
EWH370/75---754980401.28410444
EWH370/99---994980401.28410444
EWH400/47--IUSE399/48474004980401.28410444
EWH400/502385804--504980401.28410444
EWH400/61--IUSE399/61614980401.28410444
EWH400/632385805-IUSE399/63634980401.28410444
EWH400/66--IUSE399/66664980401.28410444
EWH400/72--IUSE399/73724980401.28410444
EWH400/75---754980401.28410444
EWH400/912385806-IUSE399/92914980401.28410444
EWH400/96---964980401.28410444
EWH400/99--IUSE399/98994980401.28410444
EWH400/119---1194980401.28410444
EWH400/122---1224980401.28410444
EWH400/182---1824980401.28410444
EWH417/50---504174980401.28410444
EWH417/75---754980401.28410444
EWH417/99---994980401.28410444

Characteristic Loads - I-Joist Headers

Tuotenro Fasteners Characteristic Capacities [kN]
Face
(Flange B)
Top
(Flange E)
Joist
(Flange C)
R1,k R2,k
Ø5 Holes Tri Holes Ø5 Holes Ø5 Holes Tri Holes LVL I-Joist
36mm
LVL I-Joist
39mm
SS I-Joist
45mm
LVL I-Joist
Enhanced
SS I-Joist
Enhanced
LVL I-Joist
36mm
LVL I-Joist
39mm
SS I-Joist
45mm
LVL, Glulam
Solid Sawn Timber
N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35
EWH (TF)8-44-1111131312.112.1----2.32.32.52.53.53.53.53.5
EWH (TF + 6 TRI)8644-------18.318.318.218.22.32.32.52.53.53.53.53.5
EWH (TF + 8 TRI)8844-------19.919.919.619.62.32.32.52.53.53.53.53.5
EWH (TF + 10 TRI)81044-------20.320.320.620.62.32.32.52.53.53.53.53.5
EWH (FF)8--4-669.29.288----2.32.32.52.53.53.53.53.5
EWH (FF + 6 TRI)86-4-------15.515.516.316.32.32.32.52.53.53.53.53.5
EWH (FF + 8 TRI)88-4-------16.916.916.616.62.32.32.52.53.53.53.53.5
EWH (FF + 10 TRI)810-4-------17.617.617.717.72.32.32.52.53.53.53.53.5

Footnote:    

→   (TF) = Top Fix     |    (FF) = Face Fix     |     ( +6 TRI) =  quanity of additional face nails installed through the triangular holes

→   For EWH > 300mm deep, a backer block installed onto the front face of the supporting I-joist is required for the standard performance values to apply. The installation of the backer block is to be in accordance to the I-Joist manufacturers specification

→   The enhanced installation requires a backer block to be installed onto the front face of the supporting I-joist, and the specified number of triangular holes to be filled.  The installation of the backer block is to be in accordance to the I-Joist manufacturers specification

→   R2 values relate to the joist type supported by the hanger

 

Safe Working Loads - I-Joist Headers

Tuotenro Fasteners Safe Working Loads [kN]
Face
(Flange B)
Top
(Flange E)
Joist
(Flange C)
R1,SWL,LT R2,SWL,ST
Ø5 Holes Tri Holes Ø5 Holes Ø5 Holes Tri Holes LVL I-Joist
36mm
LVL I-Joist
39mm
SS I-Joist
45mm
LVL  I-joist
Enhanced
SS I-Joist
Enhanced
LVL I-Joist
36mm
LVL I-joist
39mm
SS I-Joist
45mm
LVL, Glulam,
Solid Sawn Timber
N3.75x30 N3.75x30 N3.75x30 N3.75x30 N3.75x30 N3.75x30 N3.75x30 N3.75x30 N3.75x30
EWH (TF)8-44-4.65.45--1.21.31.81.8
EWH (TF + 6 TRI)8644----7.67.61.21.31.81.8
EWH (TF + 8 TRI)8844----8.38.21.21.31.81.8
EWH (TF + 10 TRI)81044----8.58.61.21.31.81.8
EWH (FF)8--4-2.53.83.3--1.21.31.81.8
EWH (FF + 6 TRI)86-4----6.56.81.21.31.81.8
EWH (FF + 8 TRI)88-4----76.91.21.31.81.8
EWH (FF + 10 TRI)810-4----7.37.41.21.31.81.8

Footnote:    

→   (TF) = Top Fix     |    (FF) = Face Fix     |     ( +6 TRI) =  quanity of additional face nails installed through the triangular holes

→   For EWH > 300mm deep, a backer block installed onto the front face of the supporting I-joist is required for the standard performance values to apply. The installation of the backer block is to be in accordance to the I-Joist manufacturers specification

→   The enhanced installation requires a backer block to be installed onto the front face of the supporting I-joist, and the specified number of triangular holes to be filled.  The installation of the backer block is to be in accordance to the I-Joist manufacturers specification

→   R2 values relate to the joist type supported by the hanger

 

 

Characteristic Loads - Metal Web Headers

Tuotenro Fasteners Characteristic Capacities [kN]
Face
(Flange B)
Top
(Flange E)
Joist
(Flange C)
R1,k R2,k
Ø5 Holes Tri Holes Ø5 Holes Ø5 Holes Tri Holes Metal Web Metal Web
Enhanced
Metal Web LVL, Glulam
Solid Sawn Timber
N3.75x30 CNA4.0x35 CSA5.0x50 N3.75x30 CNA4.0x35 CSA5.0x50 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35
EWH (TF)8-44-131316.4---3.53.53.53.5
EWH (TF + 6 TRI)8644----17.117.117.43.53.53.53.5
EWH (TF + 8 TRI)8844----181818.33.53.53.53.5
EWH (TF + 10 TRI)81044----18.618.618.93.53.53.53.5
EWH (FF)8--4-9.99.913.7---3.53.53.53.5
EWH (FF + 6 TRI)86-4----15.515.516.63.53.53.53.5
EWH (FF + 8 TRI)88-4----17.317.318.43.53.53.53.5
EWH (FF + 10 TRI)810-4----19.119.120.23.53.53.53.5

Footnote:    

→   (TF) = Top Fix     |    (FF) = Face Fix     |     ( +6 TRI) =  quanity of additional face nails installed through the triangular holes

→   Enhanced installation requires a 18mm plywood gusset to be fixed to the face of the metal web joist. The plywood gusset is to be at least 400mm long and full depth of the metal web joist. The plywood gusset is installed with 8 No ESCR8.0x80mm screws. The screws are to be positioned in accordance to illustration within the Installation Notes section.

→   R2 values relate to the joist type supported by the hanger

 

Safe Working Loads - Metal Web Headers

Tuotenro Fasteners Safe Working Loads [kN]
Face
(Flange B)
Top
(Flange E)
Joist
(Flange C)
R1,SWL,LT R2,SWL,ST
Ø5 Holes Tri Holes Ø5 Holes Ø5 Holes Tri Holes Metal Web Metal Web
Enhanced
Metal Web LVL, Glulam,
Solid Sawn Timber
N3.75x30 CSA5.0x50 N3.75x30 CSA5.0x50 N3.75x30 N3.75x30
EWH (TF)8-44-5.46.8--1.81.8
EWH (TF + 6 TRI)8644---7.17.31.81.8
EWH (TF + 8 TRI)8844---7.57.61.81.8
EWH (TF + 10 TRI)81044---7.87.91.81.8
EWH (FF)8--4-4.15.7--1.81.8
EWH (FF + 6 TRI)86-4---6.56.91.81.8
EWH (FF + 8 TRI)88-4---7.27.71.81.8
EWH (FF + 10 TRI)810-4---88.41.81.8

Footnote:    

→   (TF) = Top Fix     |    (FF) = Face Fix     |     ( +6 TRI) =  quanity of additional face nails installed through the triangular holes

→   Enhanced installation requires a 18mm plywood gusset to be fixed to the face of the metal web joist. The plywood gusset is to be at least 400mm long and full depth of the metal web joist. The plywood gusset is installed with 8 No ESCR8.0x80mm screws. The screws are to be positioned in accordance to illustration within the Installation Notes section.

→   R2 values relate to the joist type supported by the hanger

 

Characteristic Loads - Solid Headers

Tuotenro Fasteners Characteristic Capacities [kN]
Face
(Flange B)
Top
(Flange E)
Joist
(Flange C)
R1,k R2,k
Ø5 Holes Tri Holes Ø5 Holes Ø5 Holes Tri Holes LVL Glulam C24 Solid
Sawn Timber
LVL I-Joist
36mm
LVL I-Joist
39mm
SS I-Joist
45mm
Metal Web LVL, Glulam
Solid Sawn Timber
N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35
EWH (TF)8-44-15.515.512.912.912.812.82.32.32.52.53.53.53.53.53.53.5
EWH (TF + 6 TRI)8644-18.818.818.518.517.617.62.32.32.52.53.53.53.53.53.53.5
EWH (TF + 8 TRI)8844-1919191918.518.52.32.32.52.53.53.53.53.53.53.5
EWH (TF + 10 TRI)81044-20.420.419.419.419.119.12.32.32.52.53.53.53.53.53.53.5
EWH (FF)8--4-11.111.1996.66.62.32.32.52.53.53.53.53.53.53.5
EWH (FF + 6 TRI)86-4-18.718.716.316.313.413.42.32.32.52.53.53.53.53.53.53.5
EWH (FF + 8 TRI)88-4-20.420.417.917.915.215.22.32.32.52.53.53.53.53.53.53.5
EWH (FF + 10 TRI)810-4-21.321.318.618.617.117.12.32.32.52.53.53.53.53.53.53.5

Footnote:    

→   (TF) = Top Fix     |    (FF) = Face Fix     |     ( +6 TRI) =  quanity of additional face nails installed through the triangular holes.

→   Solid timber refers to LVL, Glulam or Solid Sawn Timber

→   R2 values relate to the joist type supported by the hanger

 

Safe Working Loads - Solid Headers

Tuotenro Fasteners Safe Working Loads [kN]
Face
(Flange B)
Top
(Flange E)
Joist
(Flange C)
R1,SWL,LT R2,SWL,ST
Ø5 Holes Tri Holes Ø5 Holes Ø5 Holes Tri Holes LVL Glulam C24 Solid
Sawn Timber
LVL I-Joist
36mm
LVL I-joist
39mm
SS I-Joist
45mm
Metal Web LVL, Glulam,
Solid Sawn Timber
N3.75x30 N3.75x30 N3.75x30 N3.75x30 N3.75x30 N3.75x30 N3.75x30 N3.75x30
EWH (TF)8-44-6.55.45.31.21.31.81.81.8
EWH (TF + 6 TRI)8644-7.87.77.31.21.31.81.81.8
EWH (TF + 8 TRI)8844-7.97.97.71.21.31.81.81.8
EWH (TF + 10 TRI)81044-8.58.181.21.31.81.81.8
EWH (FF)8--4-4.63.82.81.21.31.81.81.8
EWH (FF + 6 TRI)86-4-7.86.85.61.21.31.81.81.8
EWH (FF + 8 TRI)88-4-8.57.56.31.21.31.81.81.8
EWH (FF + 10 TRI)810-4-8.97.87.11.21.31.81.81.8

Footnote:    

→   (TF) = Top Fix     |    (FF) = Face Fix     |     ( +6 TRI) =  quanity of additional face nails installed through the triangular holes.

→   Solid timber refers to LVL, Glulam or Solid Sawn Timber   

→   R2 values relate to the joist type supported by the hanger

 

Characteristic Loads - Timber Nailer Headers

Tuotenro Fasteners Characteristic Capacities [kN]
Face
(Flange B)
Top
(Flange E)
Joist
(Flange C)
R1,k R2,k
Ø5 Holes Tri Holes Ø5 Holes Ø5 Holes Tri Holes Timber Nailer LVL I-Joist
36mm
LVL I-Joist
39mm
SS I-Joist
45mm
Metal Web LVL, Glulam
Solid Sawn Timber
N3.75x30 N3.75x75 CNA4.0x35 CSA5.0x40 N3.75x30 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 CNA4.0x35 N3.75x30
EWH (Nailer 38-74mm)4-44-9.8-9.813.92.32.52.53.53.53.53.53.53.5
EWH (Nailer 75-100mm)4-44-9.813.59.813.92.32.52.53.53.53.53.53.53.5

Footnote:

→   Timber nailers can be either Solid Sawn Timber (C24  minimum grade), LVL or Glulam

→   (38 - 50mm) refers to depth range of timber nailer

→   Minimum width of timber nailer is 89mm

→   R2 values relate to the joist type supported by the hanger

 

Safe Working Loads - Timber Nailer Headers

Tuotenro Fasteners Safe Working Loads [kN]
Face
(Flange B)
Top
(Flange E)
Joist
(Flange C)
R1,SWL,LT R2,SWL,ST
Ø5 Holes Tri Holes Ø5 Holes Ø5 Holes Tri Holes Timber Nailer LVL I-Joist
36mm
LVL I-joist
39mm
SS I-Joist
45mm
Metal Web LVL, Glulam,
Solid Sawn Timber
N3.75x30 N3.75x75 CSA5.0x40 N3.75x30 N3.75x30 N3.75x30 N3.75x30 N3.75x30
EWH (Nailer 38-74mm)4-44-4.1-5.81.21.31.81.81.8
EWH (Nailer 75-100mm)4-44-4.15.65.81.21.31.81.81.8

Footnote:

→   Timber nailers can be either Solid Sawn Timber (C24  minimum grade), LVL or Glulam

→   (38 - 50mm) refers to depth range of timber nailer

→   Minimum width of timber nailer is 89mm

→   R2 values relate to the joist type supported by the hanger

 

Characteristic Loads - SIP Headers

Tuotenro Fasteners Characteristic Capacities [kN]
Face
(Flange B)
Top
(Flange E)
Joist
(Flange C)
R1,k R2,k
Ø5 Holes Tri Holes Ø5 Holes Ø5 Holes Tri Holes SIP LVL I-Joist
36mm
LVL I-Joist
39mm
SS I-Joist
45mm
Metal Web LVL, Glulam
Solid Sawn Timber
CSA5.0x50 N3.75x30 N3.75x30 N3.75x30 N3.75x30 N3.75x30
EWH (11mm OSB)4--4-9.72.32.53.53.53.5
EWH (15mm OSB)4--4-10.22.32.53.53.53.5

Footnote:

→   SIP requires a minimum 47mm deep top rail

→   R2 values relate to the joist type supported by the hanger

 

Safe Working Loads - SIP Headers

Tuotenro Fasteners Safe Working Loads [kN]
Face
(Flange B)
Top
(Flange E)
Joist
(Flange C)
R1,SWL,LT R2,SWL,ST
Ø5 Holes Tri Holes Ø5 Holes Ø5 Holes Tri Holes SIP LVL I-Joist
36mm
LVL I-joist
39mm
SS I-Joist
45mm
Metal Web LVL, Glulam,
Solid Sawn Timber
CSA5.0x50 N3.75x30 N3.75x30 N3.75x30 N3.75x30 N3.75x30
EWH (11mm OSB)4--4-41.21.31.81.81.8
EWH (15mm OSB)4--4-4.31.21.31.81.81.8

Footnote:

→   SIP requires a minimum 45mm deep top rail

→   R2 values relate to the joist type supported by the hanger

 

Enhanced Uplift

Tuotenro Fasteners Characteristic Loads [kN] Safe Working Loads [kN]
Face
(Flange B)
Top
(Flange E)
Joist
(Flange C)
R2,k R2,SWL,ST
Ø5 Holes Tri Holes Ø5 Holes Ø5 Holes Tri Holes I-Joist +
Web Stiffener
Metal Web LVL, Glulam
Solid Sawn Timber
I-Joist
+ Web Stiffener
Metal Web LVL, Glulam,
Solid Sawn Timber
N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 N3.75x30 N3.75x30
EWH (Enhanced Uplift)46, 8 or 100, 444888888444

Footnote:

→   Fill all round and triangular holes with the relevant fastener. 

→   If the incoming joist is an I-Joist then web stiffeners are required. (The web stiffener’s size and installation requirements shall be in accordance to relevant I-Joist manufacturer’s specification). 

→   R2 values relate to the joist type supported by the hanger

 

Characteristic Loads - Solid Headers - SSH

Tuotenro Holes Characteristic Capacities [kN]
Flange B Flange C R1,k R2,k
Ø10 Ø5 Tri C24 Solid
Sawn Timber
LVL, Glulam
Solid Sawn Timber
SSH8.0x40 SSH8.0x40
EWH4448.83.5

Characteristic loads - Concrete headers

Tuotenro Fasteners Characteristic Capacities [kN]
Face
(Flange B)
Joist
(Flange C)
R1,k R2,k
Ø5 Holes Tri Holes Ø8 Ø5 Holes Tri Holes Concrete C20/25 LVL I-Joist
36mm
LVL I-Joist
39mm
SS I-Joist
45mm
LVL, Glulam
Solid Sawn Timber
Metal Web
LMAS + adhesive, WA, FM-753, BOAX N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35 N3.75x30 CNA4.0x35
EWH--44-21,3 (*)2.32.32.52.53.53.53.53.53.53.5

(*) This is the maximum characteristic value for the hanger.

The anchor capacity is to be verified separately.

Solid Sawn Timbers to be minimum C24 graded timber.

Asennus

Asennus

Installation

  • Use all specified fasteners.
  • For STANDARD installation all round holes to be filled.
  • For ENHANCED installation, all round and triangular holes to be filled, (excluding triangular hole in the hanger’s seat tab).

EWH Standard Installation Instructions – Applicable to I-Joist, Metal Web Joist & Solid Timber Headers

  1. Position EWH hanger onto the face of the supporting Joist, ensuring the seat tab is tight up against the underside of the supporting joist.
  2. Ensure hanger sides are vertical; fill all face round holes, starting from bottom upwards, with the specified fastener.
  3. For top fix installations, fold over the top flange, ensuring a tight fold line along the top edge of the supporting timber, and fill all top round holes with the specified fasteners (NOTE: Depending upon the joist depth, the fold line may be up to 6mm above the perforation lines).
  4. For face fix installations, snap off the top flange along the perforation line (NOTE: The top flange may be snapped off pre or post installation).
  5. Insert the incoming joist, ensuring it is tight against the back of the EWH (maximum allowable gap is 3mm between end of incoming joist and face of hanger) and fill all round holes in the side flanges.
  6. For instances where the supporting member is deeper than the hanger, bend the seat tab upwards so the hanger fits tight against the face of the supporting member.

EWH Enhanced Installation Instructions – Applicable to I-Joist, Metal Web Joist & Solid Timber Headers

  1. Metal Web Headers Only: Install an 18mm plywood gusset to the face of the metal web joist. The plywood gusset is to be at least 400mm long and full depth of the metal web joist. The plywood gusset is installed with 8 No ESCR8.0x80mm screws. The screws are to be positioned in accordance to illustration below.
  2. I-Joist Headers Only: Install a backer block onto the front face of the I-Joist. The backer blocks size and installation requirements shall be in accordance to the relevant I-Joist manufacturer’s specifications.
  3. Position EWH hanger onto the face of the supporting joist, ensuring the seat tab is tight up against the underside of the supporting joist’s bottom chord.
  4. Ensure hanger sides are vertical and fill all face round holes then the triangular holes, starting from bottom upwards, with the specified fastener.
  5. For top fix installations, fold over the top flange, ensuring a tight fold line along the top edge of the supporting timber, and fill the round holes with the specified fasteners (NOTE: Depending upon joist depth, the fold line may be up to 6mm above the perforation lines).
  6. For face fix installations, snap off the top flange along the perforation line (NOTE: The top flange may be snapped off pre or post installation).
  7. Insert the incoming joist, ensuring it is tight against the back of the EWH (maximum allowable gap is 3mm between end of incoming joist and face of hanger) and fill all round holes in the side flanges.
  8. For enhanced uplift installations, if the incoming joist is an I-Joist then web stiffeners are required. (The web stiffener’s size and installation requirements shall be in accordance to relevant I-Joist manufacturer’s specification). Fill all round and triangular holes with the relevant fastener.

EWH Installation Instructions – SIP

  1. It is recommended for SIP installation that the EWH is installed face fix only.
  2. Bend the seat tab upwards so the hanger fits tight against the face of the SIP.
  3. Position the EWH hanger onto the face of the SIP so that the top of the carried member will finish level with the top of the SIP.
  4. Install 4 No CSA 5.0x50mm screws through the upper 4 round holes on the face of the EWH.
  5. Tear off the hanger’s top flange, along its perforation line.
  6. Sit the carried member into the hanger and install 4 No 3.75x30mm square twist nails through the round holes into the side of the supported member.

Sertifiointi

Euroopan tekninen arviointi (ETA)

eta-17-0554.pdf (3.33 MB)

Aiheeseen liittyvät tuotteet

ZIP-paketit

Buy from Distributor

No items available.

Contact

Simpson Strong-Tie Ruotsi

Simpson Strong-Tie / Gbo Fastening Systems AB

Bruksvägen 2
59375 Gunnebo
Ruotsi